Featured Research Wetter Isn't Better New Gas Flowmeter Wins Technology Award By Mary Beckman for INEEL Research Communications August 1999 |
|||||||||||||||
The High Void-Fraction Multiphase Flowmeter developed out of the nuclear reactor safety expertise of its inventor, engineer James Fincke at the U.S. Department of Energy's Idaho National Engineering and Environmental Laboratory. The almost-maintenance-free wet gas flowmeter, which can measure the flow rate of gas and liquid from natural gas wellheads 5- to 10-times more accurately than conventional methods, in real time, and continuously, has been licensed by the Perry Equipment Corporation (PECO) in Texas and won Fincke and his PECO colleagues a 1999 R&D 100 Award.
R&D Magazine presents one hundred of these awards yearly for the most important new products. Bulent Turan, a manager in PECO's Flow Measurement Division that is testing and marketing the flowmeter, said, "The award tells us we've been going down the right track in developing this technology. This device provides the accuracy the industry has long been looking for."
Natural gas producers drill about 6000 new wells every year, and over 320,000 are expected to be in use in the United States alone by the year 2001. The natural gas flowing from these wells is usually mingled with either valuable liquid hydrocarbon or a briney mix of hydrocarbon and salt water. Current equipment to measure the volume of flow, such as mechanical test separators, costs between $50,000 and $400,000 and may be off by 10-20 percent of the volume.
The difficulty in measuring wet gas arises from the fact that gas and liquid are both fluids with different properties. In a standard flowmeter, the measured pressure of a flowing fluid can be used to determine its velocity, from which its volumetric flow rate is calculated. If the fluid is all gas or all liquid, the differential pressure accurately reflects the flow rate. With a mixture, however, there are no distinctions between the two, which results in uncertain measurement of both fluids. To determine the individual flow rates, the ratio of gas to liquid must be known. "If you know how much liquid is there," said INEEL's Fincke, "you can account for it. But that's like knowing the answer before asking the question." The inaccurate reading is a result of the design of the standard flowmeter. The basic flowmeter consists of a pipe that is constricted on one end. The constriction causes the fluid flowing through the pipe to accelerate. Before and after the constriction, two pressure measurements of the accelerating liquid are taken and the difference in pressure is converted into a volumetric flow rate.
If the fluid is single-phase, such as all gas, determining the volumetric flow rate is a simple, accurate calculation. In a gas-liquid mix, however, the denser fluidliquidaccelerates much slower than the lighter onegas. The differential pressure, then, is a skewed reading of the two fluids that overestimates the gas phase and underestimates the liquid phase.
To get around this, Fincke added a long throat past the constriction of a conventional flowmeter. The throat is long enough to give the liquid a chance to mostly catch up to the accelerating gas, and the gas and liquid components of the fluid equilibrate with new flow rates. A second differential pressure measurement of the equilibrated fluid allows the meter's computer to determine the volume flow rate with up to 20 times the accuracy of a conventional meter.
Fincke needed to determine how the equilibrated fluids behaved mathematically to calculate the correct flow rates in the wet gas flowmeter, and he did this using low-pressure air and water. "We developed a flowmeter geometry and some mathematical theory that relates the pressures to the flow rates," he said. "But then PECO wanted to do some testing with natural gas hydrocarbons at pressures similar to what you find at wellheads." Using known amounts of separated natural gas and liquid hydrocarbon, the researchers mocked up a wellhead to gather data over a wide range of conditions and with different flowmeter geometries. The tests confirmed the validity of Fincke's mathematical models. INEEL's wet gas flowmeter is accurate with wet gas that contains up to 10% liquid. If natural gas is much wetter than that, Fincke said, the producers may have a problem that needs to be addressed in the field.
The natural gas industry currently avoids the problem of taking multiphase measurements by using mechanical separators that allow the liquid and gas components to be measured independently. For small natural gas producers, these separators may be the best option, said Fincke. Natural gas flows into a tall, skinny tank, where the two components settle outliquid is removed from the bottom and gas from the top to be measured. Even so, the measurement can be off by as much as 20% of the gas volume. Large producers use portable test separators that they cart around on flatbed trucks to measure their individual wellheads a couple times a year. Test separators for small and large producers are expensive, require workers to operate and don't monitor the flow continuously. The wet gas flowmeter, on the other hand, costs between $12,000 and $20,000, has no moving parts and can operate automatically and continuously. Fincke said the wet gas flowmeter will be useful for two wide-ranging applications: reservoir management and common pipeline usage. Since the flowmeter is inexpensive and smallabout 3 feet longit can be used on all natural gas reservoirs all the time and even on offshore rigs. "The gas well problem is an area that was sorely lacking an economical solution," said Fincke.
PECO is currently beta-testing the flowmeter on natural gas wellheads. "If a producer is interested," said Fincke, "PECO will size a meter for the well, bring it out, put it on the well long enough to convince the producer that it will work and do what we say it will do. And then the producer will buy it." "We need to show the natural gas industry that the meter performs to meet their needs," said Fincke. "We hope it will become the accepted measurement solution." Co-winners of the award were PECO manager of R&D Charles Ronnenkamp, PECO software engineer Daniel J. Householder, and PECO product development engineer Darrell Kruse.
|
![]() |
![]() |
![]() |
![]() |
||