USDA Logo
ARS Logo

  Microbial Biophysics and Residue Chemistry Research
Printer FriendlyPrintable version     Email this pageEmail this page
 
Search
 
 
This site only
  Advanced Search
 
Research
  Programs and Projects
 
 
  Display category headings
Research
Research >
Research Project: Biosensor Processes for Detecting Pathogenic Bacteria in Foods

Location: Microbial Biophysics and Residue Chemistry Research

Title: Time-Resolved Fluorescence Detection of Shiga-Like Toxins Produced by Escherichia Coli 0157 and Non-0157 in Ground Beef

Authors
item Tu, Shu-I
item Golden, Marsha
item Paoli, George
item Gehring, Andrew
item Gore, Mitchell - POLYSCIENCES, INC.

Submitted to: Meeting Abstract
Publication Acceptance Date: April 7, 2004
Publication Date: September 22, 2004
Citation: Tu, S., Golden, M., Paoli, G., Gehring, A.G., Gore, M. 2004. Time-Resolved Fluorescence Detection Of Shiga-Like Toxins Produced By Escherichia Coli 0157 And Non-0157 In Ground Beef. Meeting Abstract.

Technical Abstract: Foods contaminated with Shiga like toxin (SLT)-producing Escherichia coli (STEC) pose a significant threat to public health because ingestion of small numbers of viable organisms (<100 cells) may cause hemorrhagic colitis and may lead to life-threatening sequelae such as hemolytic-uremic syndrome or thrombotic thrombocytopenic purpura in susceptible individuals. Conventional methods for detecting SLTs in foods and fecal samples include a vero cell-based cytotoxicity assay, an antibody-based direct detection assay and an indirect enzyme-linked immunosorbent assay. However, the detection limit of these methods is greater than 1 ng/mL. An immunomagnetic bead time-resolved fluorescence assay (IMB-TRF) assay was developed for the detection of Shiga-like toxins I (SLT I and SLT II). The method could detect 5 pg/mL of SLT II and 50 pg/mL of SLT I. To detect SLTs from STECs, twenty five gram ground beef patties were inoculated with 1 CFU/g of O157 or non-O157 STEC, stored at 7C for 5 h and then incubated with 100 mL of EC broth at 37C and 140 rpm shaking for 20 h. Ofloxacin was added to the ground beef at a final concentration of 10 µg/mL after 20 h of incubation to enhance toxin production. After four more hours of incubation, samples were removed and centrifuged for 10 m at 5000 rpm. The supernatant was removed and saved and a bacterial protein extraction reagent was used to lyse the cells in the pellet and release intracellular SLTs that were then recombined with extra-cellular SLTs present in the supernatant. Immunomagnetic beads coated with monoclonal antibodies specific to SLT I and SLT II were applied to capture and concentrate the toxins and captured toxins were labeled with lanthanide-tagged anti-toxin antibodies to form sandwiched complexes prior to detection by a time-resolved fluorescence (TRF) reader. TRF pathogen detection levels, defined as signals greater than or equal to 2X un-inoculated samples, were achieved in all STEC inoculated samples and no cross-reactivity was observed with either nonpathogenic microflora present on the meat or non-toxin-producing Escherichia coli K12 inoculated samples.

 
Project Team
Tu, Shu-I
Brewster, Jeffrey
Irwin, Peter
Gehring, Andrew

Publications

Related National Programs
  Food Safety, (animal and plant products) (108)

Related Projects
   Immunomagnetic Bead Technology for Pathogen Bacteria Detection

 
ARS Home |  USDA |  Home | About Us | Research | Products & Services | People & Places  | News & Events | Partnering | Careers | Contact Us | Help |
Site Map |  Freedom of Information Act |  Statements & Disclaimers |  Employee Resources |  FirstGov |  White House