NIOSH Pocket Guide to Chemical Hazards

ANTU CAS 86-88-4
C10H7NHC(NH2)S RTECS YT9275000
Synonyms & Trade Names
alpha-Naphthyl thiocarbamide, 1-Naphthyl thiourea, alpha-Naphthyl thiourea
DOT ID & Guide
1651 153
Exposure
Limits
NIOSH REL: TWA 0.3 mg/m3
OSHA PEL: TWA 0.3 mg/m3
IDLH 100 mg/m3 See: 86884 Conversion
Physical Description
White crystalline or gray, odorless powder. [rodenticide]
MW: 202.3
BP: Decomposes
MLT: 388°F
Sol: 0.06%
VP: Low
IP: ?

Sp.Gr: ?
Fl.P: NA
UEL: NA
LEL: NA

Noncombustible Solid
Incompatibilities & Reactivities
Strong oxidizers, silver nitrate
Measurement Methods
NIOSH S276 (II-5)
See: NMAM or OSHA Methods
Personal Protection & Sanitation
Skin: No recommendation
Eyes: No recommendation
Wash skin: No recommendation
Remove: No recommendation
Change: Daily

First Aid (See procedures)
Eye: Irrigate immediately
Skin: Soap wash promptly
Breathing: Respiratory support
Swallow: Medical attention immediately
Important additional information about respirator selection
Respirator Recommendations NIOSH/OSHA
Up to 3 mg/m3: (APF = 10) Any chemical cartridge respirator with organic vapor cartridge(s) in combination with a dust, mist, and fume filter/(APF = 10) Any supplied-air respirator
Up to 7.5 mg/m3: (APF = 25) Any supplied-air respirator operated in a continuous-flow mode/(APF = 25) Any powered, air-purifying respirator with organic vapor cartridge(s) in combination with a dust, mist, and fume filter
Up to 15 mg/m3: (APF = 50) Any chemical cartridge respirator with a full facepiece and organic vapor cartridge(s) in combination with a high-efficiency particulate filter/(APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister having a high-efficiency particulate filter/(APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and organic vapor cartridge(s) in combination with a high-efficiency particulate filter/(APF = 50) Any supplied-air respirator that has a tight-fitting facepiece and is operated in a continuous-flow mode/(APF = 50) Any self-contained breathing apparatus with a full facepiece/(APF = 50) Any supplied-air respirator with a full facepiece
Up to 100 mg/m3: (APF = 1000) Any supplied-air respirator operated in a pressure-demand or other positive-pressure mode
Emergency or planned entry into unknown concentrations or IDLH conditions: (APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode/(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus
Escape: (APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister having a high-efficiency particulate filter/Any appropriate escape-type, self-contained breathing apparatus
Exposure Routes inhalation, ingestion
Symptoms After ingestion of large doses: vomiting, dyspnea (breathing difficulty), cyanosis, coarse pulmonary rales; liver damage
Target Organs respiratory system, blood, liver
See also: INTRODUCTION   See ICSC CARD: 0973

NIOSH Home |  NIOSH Search  | Site Index  | Topic List | Contact Us