NIOSH Pocket Guide to Chemical Hazards

Benzoyl peroxide CAS 94-36-0
(C6H5CO)2O2 RTECS DM8575000
Synonyms & Trade Names
Benzoperoxide, Dibenzoyl peroxide
DOT ID & Guide
2085 146
2087 146
2088 146
2089 145
2090 146
Exposure
Limits
NIOSH REL: TWA 5 mg/m3
OSHA PEL: TWA 5 mg/m3
IDLH 1500 mg/m3 See: 94360 Conversion
Physical Description
Colorless to white crystals or a granular powder with a faint, benzaldehyde-like odor.
MW: 242.2
BP: Decomposes explosively
MLT: 217°F
Sol: <1%
VP: <1 mmHg
IP: ?

Sp.Gr: 1.33
Fl.P: 176°F
UEL: ?
LEL: ?

Combustible Solid (easily ignited and burns very rapidly).
Incompatibilities & Reactivities
Combustible substances (wood, paper, etc.), acids, alkalis, alcohols, amines, ethers [Note: Containers may explode when heated. Extremely explosion-sensitive to shock, heat & friction.]
Measurement Methods
NIOSH 5009
See: NMAM or OSHA Methods
Personal Protection & Sanitation
Skin: Prevent skin contact
Eyes: Prevent eye contact
Wash skin: When contaminated
Remove: When wet or contaminated
Change: Daily

First Aid (See procedures)
Eye: Irrigate immediately
Skin: Soap wash promptly
Breathing: Respiratory support
Swallow: Medical attention immediately
Important additional information about respirator selection
Respirator Recommendations NIOSH/OSHA
Up to 50 mg/m3: (APF = 10) Any dust and mist respirator except single-use and quarter-mask respirators*/(APF = 10) Any supplied-air respirator*
Up to 125 mg/m3: (APF = 25) Any supplied-air respirator operated in a continuous-flow mode*/(APF = 25) Any powered, air-purifying respirator with a dust and mist filter*
Up to 250 mg/m3: (APF = 50) Any air-purifying, full-facepiece respirator with a high-efficiency particulate filter/(APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and a high-efficiency particulate filter*/(APF = 50) Any self-contained breathing apparatus with a full facepiece/(APF = 50) Any supplied-air respirator with a full facepiece
Up to 1500 mg/m3: (APF = 2000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
Emergency or planned entry into unknown concentrations or IDLH conditions: (APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode/(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus
Escape: (APF = 50) Any air-purifying, full-facepiece respirator with a high-efficiency particulate filter/Any appropriate escape-type, self-contained breathing apparatus
Exposure Routes inhalation, ingestion, skin and/or eye contact
Symptoms Irritation eyes, skin, mucous membrane; sensitization dermatitis
Target Organs Eyes, skin, respiratory system
See also: INTRODUCTION   See ICSC CARD: 0225

NIOSH Home |  NIOSH Search  | Site Index  | Topic List | Contact Us