NIOSH Pocket Guide to Chemical Hazards

Manganese compounds and fume (as Mn) CAS 7439-96-5 (metal)
Mn (metal) RTECS OO9275000 (metal)
Synonyms & Trade Names
Manganese metal: Colloidal manganese, Manganese-55
Synonyms of other compounds vary depending upon the specific manganese compound.
DOT ID & Guide
Exposure
Limits
NIOSH REL*: TWA 1 mg/m3 ST 3 mg/m3 [*Note: Also see specific listings for Manganese cyclopentadienyl tricarbonyl, Methyl cyclopentadienyl manganese tricarbonyl, and Manganese tetroxide.]
OSHA PEL*: C 5 mg/m3 [*Note: Also see specific listings for Manganese cyclopentadienyl tricarbonyl and Methyl cyclopentadienyl manganese tricarbonyl.]
IDLH 500 mg/m3 (as Mn) See: 7439965 Conversion
Physical Description
A lustrous, brittle, silvery solid.
MW: 54.9
BP: 3564°F
MLT: 2271°F
Sol: Insoluble
VP: 0 mmHg (approx)
IP: NA

Sp.Gr: 7.20 (metal)
Fl.P: NA
UEL: NA
LEL: NA

Metal: Combustible Solid
Incompatibilities & Reactivities
Oxidizers [Note: Will react with water or steam to produce hydrogen.]
Measurement Methods
NIOSH 7300; OSHA ID121, ID125G
See: NMAM or OSHA Methods
Personal Protection & Sanitation
Skin: No recommendation
Eyes: No recommendation
Wash skin: No recommendation
Remove: No recommendation
Change: No recommendation

First Aid (See procedures)


Breathing: Respiratory support
Swallow: Medical attention immediately
Important additional information about respirator selection
Respirator Recommendations NIOSH
Up to 10 mg/m3: (APF = 10) Any dust and mist respirator except single-use and quarter-mask respirators^/(APF = 10) Any supplied-air respirator
Up to 25 mg/m3: (APF = 25) Any supplied-air respirator operated in a continuous-flow mode/(APF = 25) Any powered, air-purifying respirator with a dust and mist filter^
Up to 50 mg/m3: (APF = 50) Any air-purifying, full-facepiece respirator with a high-efficiency particulate filter/(APF = 50) Any supplied-air respirator that has a tight-fitting facepiece and is operated in a continuous-flow mode/(APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and a high-efficiency particulate filter/(APF = 50) Any self-contained breathing apparatus with a full facepiece/(APF = 50) Any supplied-air respirator with a full facepiece
Up to 500 mg/m3: (APF = 1000) Any supplied-air respirator operated in a pressure-demand or other positive-pressure mode
Emergency or planned entry into unknown concentrations or IDLH conditions: (APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode/(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus
Escape: (APF = 50) Any air-purifying, full-facepiece respirator with a high-efficiency particulate filter/Any appropriate escape-type, self-contained breathing apparatus
Exposure Routes inhalation, ingestion
Symptoms Parkinson's; asthenia, insomnia, mental confusion; metal fume fever: dry throat, cough, chest tightness, dyspnea (breathing difficulty), rales, flu-like fever; low-back pain; vomiting; malaise (vague feeling of discomfort); lassitude (weakness, exhaustion); kidney damage
Target Organs respiratory system, central nervous system, blood, kidneys
See also: INTRODUCTION   See ICSC CARD: 0174   See MEDICAL TESTS: 0131