NIOSH Pocket Guide to Chemical Hazards

Nitrogen trifluoride CAS 7783-54-2
NF3 RTECS QX1925000
Synonyms & Trade Names
Nitrogen fluoride, Trifluoramine, Trifluorammonia
DOT ID & Guide
2451 122
Exposure
Limits
NIOSH REL: TWA 10 ppm (29 mg/m3)
OSHA PEL: TWA 10 ppm (29 mg/m3)
IDLH 1000 ppm See: 7783542 Conversion 1 ppm = 2.90 mg/m3
Physical Description
Colorless gas with a moldy odor. [Note: Shipped as a nonliquefied compressed gas.]
MW: 71.0
BP: -200°F
FRZ: -340°F
Sol: Slight
VP: >1 atm
IP: 12.97 eV
RGasD: 2.46

Fl.P: NA
UEL: NA
LEL: NA

Nonflammable Gas
Incompatibilities & Reactivities
Water, oil, grease, oxidizable materials, ammonia, carbon monoxide, methane, hydrogen, hydrogen sulfide, activated charcoal, diborane
Measurement Methods
None available
See: NMAM or OSHA Methods
Personal Protection & Sanitation
Skin: No recommendation
Eyes: No recommendation
Wash skin: No recommendation
Remove: No recommendation
Change: No recommendation

First Aid (See procedures)


Breathing: Respiratory support

Important additional information about respirator selection
Respirator Recommendations NIOSH/OSHA
Up to 100 ppm: (APF = 10) Any chemical cartridge respirator with cartridge(s) providing protection against the compound of concern/(APF = 10) Any supplied-air respirator
Up to 250 ppm: (APF = 25) Any supplied-air respirator operated in a continuous-flow mode/(APF = 25) Any powered, air-purifying respirator with cartridge(s) providing protection against the compound of concern
Up to 500 ppm: (APF = 50) Any chemical cartridge respirator with a full facepiece and cartridge(s) providing protection against the compound of concern/(APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted canister providing protection against the compound of concern/(APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and cartridge(s) providing protection against the compound of concern*/(APF = 50) Any supplied-air respirator that has a tight-fitting facepiece and is operated in a continuous-flow mode*/(APF = 50) Any self-contained breathing apparatus with a full facepiece/(APF = 50) Any supplied-air respirator with a full facepiece
Up to 1000 ppm: (APF = 2000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
Emergency or planned entry into unknown concentrations or IDLH conditions: (APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode/(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus
Escape: (APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted canister providing protection against the compound of concern/Any appropriate escape-type, self-contained breathing apparatus
Exposure Routes inhalation
Symptoms In animals: anoxia, cyanosis; methemoglobinemia; lassitude (weakness, exhaustion), dizziness, headache; liver, kidney injury
Target Organs Blood, liver, kidneys
See also: INTRODUCTION   See ICSC CARD: 1234   See MEDICAL TESTS: 0165

NIOSH Home |  NIOSH Search  | Site Index  | Topic List | Contact Us