01 031926Z Nov 98 PP PP UUUU AA ZYUW FROM QUAD SERVICE MMQC FT DETRICK MD//USAMMA/AFMLO/NMLC// TO 7485 7486 7487 7488 7783 9344 9345 UNCLAS SUBJ: MMQC-98-1248 VACCINES REQUIRING AUTO JET INJECTOR APPARATUS/ INFORMATION ALERT REF A: MSG: USAMMA, DOD-MMQC-98-1019, 301738Z JAN 98 REF B: MSG: USAMMA, DOD-MMQC-97-1169, 051704Z DEC 97 01. CONNAUGHT ISSUED ALERT FOR FOL MED MATL. MFR WILL DISCONTINUE FOL VACCINE PACKAGE SIZES. REASON: REQUIRE USE OF JET INJECTOR APPARATUS THAT IS NO LONGER RECOMMENDED AS AN APPROPRIATE VACCINATION METHOD. DISPOSITION: USERS MUST READ MANUFACTURER'S PACKAGE INSERT F/SPECIAL INSTRS. PACKAGE INSERTS F/VACCINES STATE: IF ABSOLUTELY NECESSARY, SYRINGES AND NEEDLES MAY BE USED W/SUCH CONTAINERS W/CAUTION. HOWEVER, DUE TO CORING OF THE STOPPER DO NOT INSERT NEEDLE INTO VIAL MORE THAN 20 TIMES. PARTIALLY USED VIALS OF VACCINE SHOULD BE DISCARDED. DSCP POC IS CHARLES DIPERI, DSN 444-2829 OR 215-737-2829. NSN: 6505-01-131-3436 UI: PG NOM: MENINGOCOCCAL POLYSACCHARIDE VAC GRPS A C Y W-135 COMB FRDR50DOS MFR: CONNAUGHT LOT/SERIAL NUMBER(S): ALL 02. REASON AND DISPOSITION AS ABOVE. NSN: 6505-00-864-5249 UI: BT NOM: TETANUS & DIPHTHERIA TOXOIDS FOR ADULT USE ADSORBED USP 30 ML MFR: CONNAUGHT LOT/SERIAL NUMBER(S): ALL 03. AIR FORCE: SEE AFMAN 23-110, VOL 5, CHAP 19, PARA 19.7.3 FOR REQUIRED ACTIONS. FOR MAJCOMS & NGB--THIS MSG HAS BEEN TRANSMITTED TO ALL DESIGNATED SUBORDINATE MEDICAL ACTIVITIES IAW AFMAN 23-110, VOL 5, CHAP 19. 04. PASS MSG TO MEDICAL LOG OFCRS, CMD CHANNELS, PHARMACY, CLINICAL PERSONNEL, MED STAFF SECTIONS, SUPPLY OFCRS, AND SUPPORTED ACTYS/CTRS. 05. SVC SPECIFIC POCS ARE AS FOLS (FAX NOS. ARE AVAILABLE 24 HRS); ARMY: , 301-619-4300/2045, DSN: 343, FAX 2938, E-MAIL: AIR FORCE: , 301-619-4170, DSN: 343, FAX 2557, E-MAIL: NAVY: , 301-619-3085, DSN: 343, FAX 3087, E-MAIL: