NEMI Method Summary

Method Summary Information

Method Number: I-1586 Media: WATER
Revision: 1985
Method Source: U.S. Geological Survey (USGS)
Subcategory: INORGANIC Analytes in this method
Official Name: pH in Water by Electrometry Using a Glass-Electrode
Descriptive Name Water pH
Source Info: USGS Branch of Information Services
Box 25286, MS 417
Federal Center
Denver, CO 80225-0286
Phone: 303-202-4700
Citation: USGS Methods, Volume A1
78247 Byte file
Brief Method
Summary:
This method involves pH-meter operation and may be automated with commercially available instrumentation.
Scope And
Application:
This method may be used to determine the pH of any natural or treated water and any industrial or other wastewater.
Applicable
Conc Range:
None given.
Interferences: (1) Sodium error may bias results at pH > 10 unless a "low sodium error" electrode is used. (2) Coatings of oily material can impair electrode. (3) Temperature effects.
QC Requirements: Calibrate instrument using calibration standards (CAL); quality control samples (QCS); and laboratory blanks (LB) analyzed at a minimum of 1 for every 10 samples.
Sample Handling: Container Description: 125 mL polyethylene bottle.
Treatment and Handling: Use unfiltered sample to rinse bottle. Max holding time: 180 days.
Max Holding Time:
180 days
 
Relative Cost: Less than $50
4762