NEMI Method Summary

Method Summary Information

Method Number: 243.1 Media: WATER
Revision: Issued 1971; Editorial Revision 1974 and 1978
Method Source: U.S. EPA National Exposure Research Laboratory (NERL) [formerly EMSL]
Analytes in this method
Subcategory: INORGANIC
Official Name: Manganese (Atomic Absorption, Direct Aspiration)
Descriptive Name Manganese by Flame AA
Source Info: U.S.EPA National Exposure Research Laboratory (NERL)
Microbiological and Chemical Exposure Assessment Research Division (MCEARD)
[formerly the Environmental Monitoring Systems Laboratory (EMSL), Cincinnati, OH]
26 West Martin Luther King Drive
Cincinnati, Ohio 45268-0001
Fax: 513-569-7757
email: DWmethods.help@epa.gov
Citation: Methods for the Chemical Analysis of Water and Wastes (MCAWW) (EPA/600/4-79/020)
12555 Byte file
Brief Method
Summary:
A sample prepared according to EPA Method 200.0 is analyzed using a flame atomic absorption spectrometer. Specifications for instrument operation and preparation of standards are provided in the method.
Scope And
Application:
This method determines manganese by flame atomic absorption spectrometry. Sample pretreatment according to EPA Method 200.0 determines the applicability.
Applicable
Conc Range:
0.10 - 3.0 mg/L (optimal range); 0.05 mg/L (sensitivity).
Interferences: For interferences see EPA Method 200.0. Background correction is recommended as well as the necessity if standard addition is required.
QC Requirements: QC requirements for drinking water procedures are provided in method 200.0
Sample Handling: Sample handling and preservation procedures are provided in EPA Method 200.0.
Max Holding Time:
6 months (MCAWW, Table 1).
Sample Prep Met 200.0
Relative Cost: Less than $50
5330