NEMI Method Summary

Method Summary Information

Method Number: D1068A Media: WATER
Revision: 1996
Method Source: ASTM International
Subcategory: INORGANIC Analytes in this method
Official Name: Standard Test Methods for Iron in Water
Descriptive Name Iron by Atomic Absorption, Direct (Test Method A)
Source Info: ASTM International
100 Barr Harbor Drive West
Conshohocken, PA 19428
Telephone: (610) 832-9500
Fax: (610) 832-9555
Email: service@astm.org
Citation: ASTM Volume 11.01
 
Brief Method
Summary:
Iron is determined by atomic absorption spectrophotometry. Dissolved iron is determined by atomizing the filtered sample directly with no pretreatment. Total recoverable iron is determined by atomizing the sample following hydrochloric-nitric acid digestion and filtration.
Scope And
Application:
These test methods cover the determination of iron in water. Procedures are given for determining total iron, dissolved iron, and ferrous iron. Undissolved iron may be calculated from the total iron and dissolved iron determinations.
Applicable
Conc Range:
0.1 - 5.0 mg/L
Interferences: Sodium, potassium, barium, chloride and sulfate (5000 mg/L each), calcium, magnesium, chromium, manganese, cobalt, nickel, copper, zinc, palladium, silver, cadmium, tin, lead, lithium, mercury, selenium, aluminum, antimony, arsenic, vanadium, boron, and molybdenum (100 mg/L) do not interfere. Background correction (or chelation-extraction) may be necessary to determine low levels of iron in some waters.
QC Requirements:
Sample Handling: Collect the sample in accordance with Practice D 1066, Specification D 1192, or Practices D 3370, as applicable. Samples should be preserved with HNO3 or HCl (sp gr 1.42) to a pH of 2 or less immediately at the time of collection. If only dissolved iron is to be determined, the sample shall be filtered through a 0.45-um membrane filter before acidification.
Max Holding Time:
The holding time for samples can be calculated in accordance with Practice D 4841. If ferrous iron is to be determined, the sample should be analyzed as soon as possible after collection and contact with atmospheric oxygen should be minimized.
 
Relative Cost: Unknown
URL to obtain ordering information for this method:
http://www.astm.org/cgi-bin/SoftCart.exe/DATABASE.CART/PAGES/D1068.htm?E+mystore